球探网即时比分007

You are here: Home » Information » Machinery and Equipment »Text

Mining Division Controlled Turnout Device, Division Controlled Turnout Device, Jiaxing Division Controlled Turnout

Enlarge fontReduce font Release date: 2019-12-30 Views: 0
Core Tips: Mining Division Control Turnout Device, Division Control Turnout Device (Online Consultation), Jiaxing Division Control Turnout Device, ZKC127 Mining Division Control Turnout Overview Automatic control of large lane turnouts. Driver-controlled turnout device for electric locomotive driver

Mining Division Controlled Turnout Device, Division Controlled Turnout Device (Online Consulting), Jiaxing Division Controlled Turnout

Mining Division Controlled Turnout Device

ZKC127 Mining Division Control Turnout Overview ZKC-127K Division Control Turnout Device Controller can be used for automatic control of large road turnouts in coal mines. The driver of the locomotive driver uses the transmitter of the turnout control device to control the turnout position. Above the turnout, there is a display of the turnout control device to show the turnout position.

ZKC127 Mining Division Controlled Turnout Environment

a) Ambient temperature: 0 ℃ ~ + 40 ℃

b) The average relative humidity of the air: ≤95% (+ 25 ° C);

c) Atmospheric pressure: 80kPa ~ 106kPa

Main components and technical parameters of the company-controlled turnout device

Controller for ZKC-127K Division Control Turnout Device

1. Rated working voltage: AC 127V

2. Rated power: 40W

3. Intrinsically safe parameters: U0: DC12.5V, I0: 1A

ZKC-12F type transmitter for turnout device

1. Rated working voltage: DC 12V

2. Rated working current: ≤30mA

3.Effective transmission distance ≤50m

Display for ZKC-12X Division Control Turnout Device

1. Rated working voltage: DC 12V

2.Effective display distance ≤30m

3. Display mode: LED light icon

GUC15 Mine Intrinsically Safe Position Sensor

1. Rated working voltage: DC 12V

2. Contact capacity: DC12.5V / 1A

3. Effective sensing distance: ≤15㎜

AHS-12 Mine Intrinsically Safe Control Button

1. Rated working voltage: DC 12V

2. Rated working current: ≤5mA

3. The button is normally open

CFHC10-0.8 Mine intrinsically safe pneumatic solenoid valve

1. Rated working voltage: DC 12V

2. Rated working current: ≤266mA

3. Input air pressure: 0.2 ~ 0.8MPa

[ Information search ] [ Add to favorites ] [ Tell a friend ] [ Print this article ] [ Report violation ] [ Close window ]

条[查看全部]相关评论 A total of 0 [View All] Related Comments

Recommended Photo
Recommended information
Click Ranking
Industry AssociationRecord informationTrusted website